Energy Efficiency for Buildings

ENERGY EFFICIENCY

Energy Efficiency for Buildings

Energy efficiency consulting finds where a building wastes energy and which measures pay back first. BuildGreen audits, models and verifies the energy performance of new and existing buildings, so investment goes to the measures with the largest saving.

Contact Us

ENERGY EFFICIENCY

From Audit to Verified Savings

Each study ends in a ranked list of measures with their cost, saving and payback, ready for an investment decision, a certification credit or an EU Taxonomy file.

Energy Audits for Existing Buildings

01

Energy Audits for Existing Buildings

An energy audit shows where an existing building uses and wastes energy. We analyse metered consumption, inspect the heating, cooling, ventilation and lighting systems, and review how the building is operated against how it was designed.

The result is a list of improvement measures, each with its estimated saving, cost and payback, ranked so that owners and property managers can decide what to do this year and what to plan for the next refurbishment.

Dynamic Energy Modelling

02

Dynamic Energy Modelling

A dynamic energy model simulates a building hour by hour across a full year, using its geometry, construction, systems, occupancy and local weather. It predicts energy use before anything is built or changed.

We use it to compare design options, to size the effect of a retrofit, and to produce the energy calculations that BREEAM, LEED and the EU Taxonomy ask for.

Retrofit and Efficiency Roadmaps

03

Retrofit and Efficiency Roadmaps

A retrofit roadmap turns audit findings into a sequence of works. Measures are grouped by cost and disruption and timed with lease events, plant replacement and planned refurbishment, so that each step is done when it is cheapest to do.

For portfolios, we rank buildings by saving potential, so capital goes first to the assets where it achieves the most.

Renewable Energy Feasibility

04

Renewable Energy Feasibility

A feasibility study checks which on-site renewable systems suit a building: photovoltaics, heat pumps, solar thermal or geothermal. It weighs the available roof and plot area, the building's demand profile, the grid connection and the local regulations.

The study gives the expected yield, the share of demand covered, the investment and the payback for each option.

HOW AN ENERGY STUDY RUNS

How it’s done

  1. 01

    Measure

    We collect utility and meter data, drawings and equipment lists, and inspect the building on site to see how it really operates.

  2. 02

    Model

    We build the energy balance or a dynamic model of the building and calibrate it against the measured consumption.

  3. 03

    Prioritise

    Each measure gets a saving, a cost and a payback, and the measures are ranked into a plan that fits your budget and timing.

  4. 04

    Verify

    After the works, measured consumption is compared with the prediction, so the savings are confirmed rather than assumed.

COST

What the cost depends on

  1. 01

    Building size and systems

    The floor area and how many heating, cooling and ventilation systems there are to inspect.

  2. 02

    Data already available

    Metered data and drawings shorten the work; missing data has to be measured on site.

  3. 03

    Depth of the study

    A walk-through audit, a detailed audit or a calibrated dynamic model.

  4. 04

    Number of buildings

    Portfolios share method and reporting, which lowers the cost per building.

The figure depends on your building, so it comes in an offer, after a short discussion about the project. Tell us the building type, its size, the stage it is at and the level you are aiming for.

Request an offer

FAQS

Common questions about energy efficiency

What to fund first, what an audit and a model each tell you, and how energy performance feeds BREEAM, LEED and the EU Taxonomy.

More FAQs

Fund first the measures with the lowest cost per unit of energy saved. In most buildings these are operational: correcting schedules and setpoints, optimising the building management system and upgrading lighting. Replacing heating, cooling and ventilation plant comes next, timed with the end of its service life, and facade or roof upgrades are usually tied to a planned refurbishment. An energy audit ranks the measures by cost, saving and payback.

An energy audit examines an existing building: it analyses metered consumption, inspects systems and lists improvement measures with their savings. Energy modelling simulates a building hour by hour in software, and is used to compare design options, to predict the effect of a retrofit and to demonstrate performance for BREEAM or LEED.

An energy efficiency study starts from utility bills or meter data for at least one full year, architectural and services drawings, the equipment list, operating hours and, where available, trend data from the building management system. Missing data can be measured on site during the audit.

Yes. Energy is the highest-weighted topic in both BREEAM and LEED, so better energy performance moves a building up a rating level faster than any other category. The EU Taxonomy sets energy performance thresholds for new buildings, renovations and acquired buildings, and an energy model or audit is the evidence used to show them.

The duration of an energy audit depends on the size and complexity of the building and on how much metered data already exists. It includes data collection, a site inspection, analysis and a report with ranked measures. BuildGreen confirms the timeline in the offer, after a short scoping discussion.

CONTACT US

Looking for a sustainability solution?

Get in touch with our team of sustainability consultants to explore tailored solutions in ESG strategy, carbon footprint reduction, and green building certifications (BREEAM, LEED, WELL, EDGE). We provide personalized guidance to help organizations meet regulations, achieve net zero targets, and add long-term value to their assets.

Contact Us
BuildGreen sustainability consultants at work
Bucharest, RomaniaCotroceni Park, 7 Iuliu Maniu Boulevard